Features
- Switch mode technology for high efficiency, lightweight and quiet operation
- Automatic operation for ALL Lead Acid Batteries Flooded, AGM or Gel Cell
- Can charge 2 banks of batteries simultaneously, no isolator necessary
- Can be used as a power supply or DC UPS when used in conjunction with a battery
- User Configurable AC Input voltage 120 or 230 VAC, 50 / 60 Hz
- User Selectable ( by DIP Switch) for 2 or 3 stage, rapid and safe charging of standalone and loaded Lead Acid Batteries
- “Half Power Mode” reduces maximum charging current to half the rated capacity, allows for safe charging of lower capacity batteries
- Voltmeter and Ammeter for monitoring
- Fan cooled based on output current
- Protections: Short circuit, overload, reverse battery connection and over temperature
- Includes temperature sensor to prevent under/overcharging of battery if temperature varies extensively
Specification
Input: 120 VAC 50/60 Hz (default) or 230 VAC 50/60 Hz (by internal jumper setting)
Output: 24 VDC
Amps: 25
Remote Control: 900-RC
Weight: 9 (lbs)
Weight: 4.1 (kg)
Dimensions: 13.03 x 9.6 x 3.82 (in)
Dimensions: 331 x 244 x 97 (mm)
Safety: Intertek ETL Listed to meet UL Standard UL-1564, EMI Compliant to FCC Part 15(B), Class B